Measurement Uncertainty Values for Chemical Analysis
Download to see full Measurement Uncertainty, Reporting Ranges and Materials Testing Decision Rules
Site | Accreditation | C | Mn | Si | S | P | Cu | V | Cr | Ni |
InfraBuild Steel – Laverton Steel Mill | 1726 | 0.014 | 0.020 | 0.008 | 0.004 | 0.001 | 0.010 | 0.001 | 0.006 | 0.005 |
InfraBuild Steel – Sydney Steel Mill | 2482 | 0.012 | 0.017 | 0.009 | 0.003 | 0.002 | 0.006 | 0.001 | 0.003 | 0.003 |
Bureau Veritas Minerals – Whyalla | 794 | 0.006 | 0.008 | 0.006 | 0.001 | 0.001 | 0.001 | 0.002 | 0.060 | 0.002 |
Site | Accreditation | Sn | Mo | Al | Nb | Ti | B | N | Ca | Ceq |
InfraBuild Steel – Laverton Steel Mill | 1726 | 0.001 | 0.001 | 0.002 | 0.001 | 0.0002 | 0.0005 | 0.015 | ||
InfraBuild Steel – Sydney Steel Mill | 2482 | 0.001 | 0.001 | 0.001 | 0.001 | 0.0004 | 0.0001 | 0.003 | ||
Bureau Veritas Minerals – Whyalla | 794 | 0.001 | 0.004 | 0.058 | 0.001 | 0.0010 | 0.0001 | 0.005 | 0.0003 |
InfraBuild Steel – Laverton Steel Mill and InfraBuild Steel – Sydney Steel Mill measure uncertainty as an ‘expanded uncertainty’ including uncertainty from sampling in the calculations. The expanded uncertainty has a coverage factor, K of 1.96.
Revision: November 2019